13-MAINTENANCE AND CLEANING
REPLACEMENT OF OVERPRESSURE SILICON DAMPER FOR COMBUSTION CHAMBER
The overpressures sillicon damper “G” for combustion chamber (g. A) shall be replaced with a new one yearly (during the periodical
maintainance) in order to keep the overpressure safety system ecient.
For replacement use the following instructions
remove the top
remove the rst lateral ceramic covering / metal covering (in accordance with the model)
unscrew the screw-washer-damper-spacer shown in g. A/C (operate same way on both sides)
Install the new kit as follows:
Prepare the screw-washer-damper-spacer alligned as shown in g.C and screw them in the structure.
screw it completely
Check now the proper compression of dampers, using the gauge included in the kit:
lay the gauge on the lid (g.B); the gauge has to lay completely, while the head of the screw has to be in contact with the gauge. If
it’s not the case, register the screw accordingly.
A
C
B
G